Putting on the Pressure

A 60 yo male presents to EMS with several hours of chest pressure and diaphoresis. A 12 lead ECG is obtained following a 10 beat run of non sustained ventricular tachycardia. Despite the EMT's excitement at "firing up the paddles," the paramedic administers 324 mg of aspirin and prepares for transport to the nearest facility capable of percutaneous coronary intervention. Your partner informs you that the monitor discerns the presence of a paced rhythm. The patient has no previous medical history.


12 LEAD ECG:




12 LEAD ECG Analysis:

A sinus rhythm is present and the rate is regular. Diffuse and concerning ST segment changes appear in this tracing. First, pathologic ST segment elevation occurs in leads V2, V3 and V4. Q waves also appear throughout the tracing. The monitor misinterprets the ischemic Q wave as a pacer spike. The QRS is narrow, so an interventricular conduction delay is less likely responsible for the "false pacer" call. Reciprocal changes appear in lead aVF. There is minimal J point depression in lead III and V6. The baseline is also irregular.


12 Lead ECG Interpretation: 

Sinus rhythm, anterior wall ST segment myocardial infarction.

Comments:
  • It is difficult to discern the location of the anatomic lesion based upon this ECG. The large ST segment elevation in the precordial leads suggests involvement of the LAD. The findings of lateral wall ischemia could implicate the circumflex as well. 
  • The run of VT was likely due to ventricular irritability. Remember that the most devastating complications of anterior wall ischemia are lethal dysrhythmia and cardiogenuc pulmonary edema 
  • Pathologic Q waves generally follow a few rules: (1) larger than a third of the corresponding R wave or (2) measure in excess of 0.03 seconds. Q waves that accompany poor R wave progression are more likely to indicate ischemia. 

2 comments:

  1. I think this is also a great example of a "fragmented QRS" indicative of electrical activity moving around infarcted/electrically silent scar. (Take 2012, Das 2006)

    ReplyDelete
    Replies
    1. Well said- a subtle but very important observation. Especially in this case where a monitor's interpretation can be misleading. Thank you for the reference as well.